This box provides GFCI Protection to (6) circuit multicables that are typically feeding 6 lighting instrumetns. Typical GFCI protection will not work when the circuits are dimmed to a threshold level. The GFCIs in this box is fed by a seperate, non-dimmed NEMA 5-15 Edison circuit.
Features & Benefits
Complies with NEC and OSHA requirements for personnel protection in temporary wiring installations
Separate, non-dimmed circuit feeds the GFCI units to provide protection for dimmable loads
Heavy duty molded rubber enclosure is fully insulated, resistant to shock, impact, corrosion and weather
NEMA 3R Weatherproof
Specifications
Enclosure:
PAGODA
Input:
(1) 6-Circuit, 20 A, 120 VAC LSC 19 Pin panel mount inlet
Output:
(1) 6-Circuit, 20 A, 120 VAC LSC 19 Pin panel mount receptacle
GFCI Protection:
(7) 20 A, 125 VAC Industrial Grade Class A GFCI switches (manual test and reset buttons)--one for each circuit, plus one for the seperate power circuit
GFCI Power:
(1) NEMA 5-15, 15 A, 2P3W, 125 VAC inlet
(feeds each of the GFCI units with non-dimmed power)