Description A feature rich 19” rack mountable dimmer pack with twelve 1500W dimmers (versions with 2500W or 6000W dimmers are available). Twelve NEMA 5-20 connectors are provided for the outputs.
Catalog Number D125DX-520-LG
Markets Served Theatical, Motion Picture, Live Event
Features & Benefits
Twelve 1500w dimmers
Twelve NEMA 5-20 output connectors
Easy to operate LED user interface for addressing and setup
Controlled with DMX512, 0-10VDC analog, or on-board controller
DMX start address or dimmer soft patching
100 internal presets
Built in chase functions
Programmable non-dim
Lamp pre-heat feature
Selectable output voltage top limit for low voltage fixtures
Circuit breaker protected (no fuses)
Neutral and ground miswiring protection
Broadcast quality filtering
Integrated DMX termination switch
Suitable for resistive or inductive loads
Specifications Power Capability:
Twelve dimmers, 1500 watts each
Control :
Industry standard DMX512 control or analog 0-10VDC. Levels may also be selected from the front panel without need for external control.
Control Input :
Optically isolated DMX input. Gold plated 5 pin XLR DMX in and thru connectors. Analog connector is 15-pin D-sub. A DMX termination switch is provided.
Front Panel Display:
Display provides clear indication of power, DMX data, DMX start address and soft-patching DMX assignments, pre-set levels and non-dim assignments.
Output Regulation:
± 2%.
Output Limit:
Output voltage may be limited on a dimmer-by-dimmer basis to accommodate low-voltage loads.
Loads :
Resistive or inductive
DMX Channel Assignment:
Start address or soft patch mode (any or all dimmer channels may be assigned to any DMX control channel).
Lamp Pre-Heat:
A minimum output level may be programmed into each dimmer.
Neutral Error©:
Innovative voltage sensing circuitry shuts down the dimmer when neutral or ground conductors rise to a potentially dangerous level.
Non-Dim:
The unit may be configured to operate as a solid-state relay.
Filtering :
Broadcast quality chokes. Dimmer’s rise time shall not exceed 450µs at full load.
Voltage Monitor:
Input power connections may be verified by phase LEDs on the front panel display.
Input Power:
One, two or three phase 120VAC
Overcurrent Protection :
Magnetic circuit breakers
Output Connection:
Twelve NEMA 5-20 connectors
Cooling :
Thermostatically controlled fan
Construction : Steel chassis with black baked epoxy finish.
Rack Space Required:
Two RU per pack
Approvals :
UL and cUL
Agency Approvals Yes
Enclosure Type Metal